Skip to content

Products

Exicom

Exicom Harmony Series Gen 2.0 DC fast charging — 60 to 240 kW in one cabinet family, CCS-2 up to 1,000 V, supplied and installed by EnerzyZone as part of a complete EPC scope.

Supplied as part of a full EPC scope

  • Four power classes: 60, 120, 180 and 240 kW, built from 30 kW and 40 kW modules
  • CCS-2 outlets up to 1,000 Vdc — covers current and next-generation EVs
  • OCPP v1.6j (JSON), so the charger can move between CMS platforms
  • System efficiency above 95%, THD under 5%, power factor above 0.98
  • IP 54 / IK10 enclosure with de-rating beyond 55 °C instead of shutdown
  • Supplied with site survey, electrical design, installation and commissioning

Ranges

  • Harmony Gen 2.0 — 60 / 120 kW

    Commercial sites and fleet depots. One cabinet, 30 kW modules, up to two CCS-2 outlets at 200 or 250 A.

  • Harmony Gen 2.0 — 180 / 240 kW

    Highway corridors and high-throughput hubs. 30 kW and 40 kW modules, outlet current up to 375 A on the 240 kW build.

Specifications

Manufacturer figures, transcribed from Exicom's own Rev00 technical specification sheets for the Harmony Series — Gen 2.0. Expand a model to see the full sheet.

Harmony Gen 2.0 — 60 / 120 kW

60 / 120 kWCCS-2, up to 2 outletsOCPP v1.6j

Commercial charging sites and fleet depots. Built around a 30 kW conversion module, so the same cabinet scales between 60 and 120 kW.

Power output

Harmony Gen 2.0 — 60 / 120 kWPower output
Maximum output power rating60 / 120 kW, with 30 kW conversion module
DC output voltage rating200 – 1,000 Vdc
Outlet 1CCS-2, 200 / 250 A
Outlet 2 (optional)CCS-2, 200 / 250 A
Simultaneous EV charging1 or 2

Mains input

Harmony Gen 2.0 — 60 / 120 kWMains input
Input voltage (nominal)380 / 400 / 415 Vac
Input voltage range320 – 460 Vac
Network connectionTN-S
AC wiring3-phase (L1, L2, L3), N, PE
Input frequency50 / 60 Hz (range 45 – 65 Hz)
AC input current & kVA93 A, 65 kVA @400 Vac (60 kW) · 186 A, 130 kVA @400 Vac (120 kW)
Conversion efficiency≥ 95% at 50–100% load, nominal input
THD(i)< 5% at 50–100% load, nominal input
Power factor> 0.98 at 50–100% load, nominal input

Protection

Harmony Gen 2.0 — 60 / 120 kWProtection
Protection and safetyOver current, under voltage, over voltage, residual current, surge protection, short circuit, over temperature, ground fault, insulation fault, emergency stop

Interface & communication

Harmony Gen 2.0 — 60 / 120 kWInterface & communication
Display10″ TFT LCD touch screen
Support languageEnglish (optional multilingual interface)
Emergency switchRed mushroom push button
User authenticationRFID, mobile app, OTP, QR code
Energy metering (non-billing)Included
Energy metering (MID)AC input MID meter (optional)
Visual indication (LED)Supply present, state of charging, error
RFIDMIFARE — ISO/IEC 14443A
ConnectivityEthernet (RJ45)
Modem (option)4G LTE (EU)
Communication protocolOCPP v1.6j (JSON)
Battery backup~30 minutes for the controller unit

Configuration

Harmony Gen 2.0 — 60 / 120 kWConfiguration
Software updateOver the air, via the Exicom web portal
Control and setupOCPP v1.6j, local (passcode controlled), Exicom web portal

Mechanical

Harmony Gen 2.0 — 60 / 120 kWMechanical
Ingress protectionIP 54 per IEC 60529
Impact resistanceIK10 per IEC 62262
Dimensions (H×W×D)1,852 × 756 × 534 mm
Weight≈270 kg without SMR · ≈360 kg with SMR
Charging cable length5 m (7 m optional)
MaterialTexture-finish powder-coated SECC

Harmony Gen 2.0 — 180 / 240 kW

180 / 240 kWCCS-2, up to 2 outletsOCPP v1.6j

Highway corridors and high-throughput hubs. Uses 30 kW and 40 kW conversion modules, and the 240 kW build raises outlet current to 375 A.

Note: Exicom's Rev00 sheet for this model reuses the 60/120 kW feature page verbatim, so that page still reads “delivers up to 120 kW”, and one row in the table below is still labelled “AC input kVA 60/120kW” while carrying the correct 180/240 kW values. The specification figures here are taken from this model's own table. Confirm the configuration with us before specifying.

Power output

Harmony Gen 2.0 — 180 / 240 kWPower output
Maximum output power rating180 / 240 kW, with 30 kW / 40 kW conversion module
DC output voltage rating200 – 1,000 Vdc
Outlet 1CCS-2, 200 / 250 / 300 A (375 A on the 240 kW build)
Outlet 2 (optional)CCS-2, 200 / 250 / 300 A (375 A on the 240 kW build)
Simultaneous EV charging1 or 2

Mains input

Harmony Gen 2.0 — 180 / 240 kWMains input
Input voltage (nominal)380 / 400 / 415 Vac
Input voltage range320 – 460 Vac
Network connectionTN-S
AC wiring3-phase (L1, L2, L3), N, PE
Input frequency50 / 60 Hz (range 45 – 65 Hz)
AC input current & kVA280 A, 194 kVA @400 Vac · 372 A, 258 kVA @400 Vac
Conversion efficiency≥ 95% at 50–100% load, nominal input
THD(i)< 5% at 50–100% load, nominal input
Power factor> 0.98 at 50–100% load, nominal input

Protection

Harmony Gen 2.0 — 180 / 240 kWProtection
Protection and safetyOver current, under voltage, over voltage, residual current, surge protection, short circuit, over temperature, ground fault, insulation fault, emergency stop

Interface & communication

Harmony Gen 2.0 — 180 / 240 kWInterface & communication
Display10″ TFT LCD touch screen
Support languageEnglish (optional multilingual interface)
Emergency switchRed mushroom push button
User authenticationRFID, mobile app, OTP, QR code
Energy metering (non-billing)Included
Energy metering (MID)AC input MID meter (optional)
Visual indication (LED)Supply present, state of charging, error
RFIDMIFARE — ISO/IEC 14443A
ConnectivityEthernet (RJ45)
Modem (option)4G LTE (EU)
Communication protocolOCPP v1.6j (JSON)
Battery backup~30 minutes for the controller unit

Configuration

Harmony Gen 2.0 — 180 / 240 kWConfiguration
Software updateOver the air, via the Exicom web portal
Control and setupOCPP v1.6j, local (passcode controlled), Exicom web portal

Mechanical

Harmony Gen 2.0 — 180 / 240 kWMechanical
Ingress protectionIP 54 per IEC 60529
Impact resistanceIK10 per IEC 62262
Dimensions (H×W×D)1,852 × 756 × 648 mm
Weight≈290 kg without SMR · ≈410 kg with SMR
Charging cable length5 m (7 m optional)

Stated across the Harmony Gen 2.0 family

Exicom lists these on both sheets. Model-specific figures are in the tables above.

  • System efficiency greater than 95%, cutting energy waste and running cost
  • Dynamic load sharing in 30 kW steps (optional) across multiple charging stacks
  • Intelligent de-rating beyond 55 °C rather than shutting down
  • Supports battery systems up to 1000 V, covering current and next-generation EVs
  • CCS-2 (ISO/DIN) and full OCPP 1.6 compliance — the charger can move between CMS platforms
  • Smart multi-stack charging profiles across several EVs
  • Remote Monitoring System for live diagnostics, data logging and fault management, with a rule engine
  • Ring Net support — two chargers can be linked on site to raise total output
  • 10-inch touchscreen, optional multilingual interface
  • Optional customer-specific decals for site branding

Standard and Premium builds

Both power classes are offered in two build levels. Premium adds to the standard build rather than replacing it.

Standard

  • Exicom's own OS, so the platform can be extended later
  • Very low reactive losses
  • Multi-stack smart charging profiles
  • Power sharing between two chargers via ring technology
  • Light indication showing state of charge per gun
  • Flexible authentication process

Premium — adds

  • Up to 8 screen savers before the startup screen
  • Multilingual interface — up to 6 regional and 2 foreign languages
  • Dual arm-based cable management
  • Ambient lighting
  • Ergonomic gun holder
  • Advanced RMS with rule engine and AI-based insights

Source: Exicom Harmony Series — Gen 2.0 technical specifications, Rev00, the Rev00 sheets published on the EnerzyZone site in January 2026. Manufacturers revise hardware — we confirm the exact configuration, including outlet current and module count, in writing before any order.

Which model fits your site?

A spec sheet cannot tell you which unit your site can actually run — that depends on your available load, dwell time and the vehicles you expect. Tell us about the site and we will recommend a configuration, including when a cheaper one would serve you just as well.